Installation Key Points:The position of the magnetic switch determines the timing of signal activation. During installation, first run the cylinder to the sensing position, then secure the reed switch. Be sure not to install the two reed switches too close to each other, as their magnetic fields may interfere with one another.
Troubleshooting for lack of sensitivity:If the signal is unstable, first checkIs the reed switch an NPN or PNP type?(Match the PLC input points); second, check whether the magnetic ring on the cylinder piston has come loose or lost its magnetization (this issue may be caused by forceful impacts); finally, verify that the installation position is within the effective stroke range of the magnetic ring.