Can blade cylinders be used in cleanrooms? How can they be protected against dust?
Can blade cylinders be used in cleanrooms? How can they be protected against dust?
A: Standard‑version blade cylinders have an IP40 ingress protection rating and are suitable for general industrial environments. If used in a Class 1,000 or Class 10,000 cleanroom, the following measures must be taken:
Material Upgrade: OrderStainless steel material (such as SUS304)Blade-type cylinder, designed to prevent surface oxide scale from causing contamination.
Dust-proof attachment: Add-onAnti-fouling strip (bellows cover)orTelescopic shield. This effectively prevents the lubricant on the slide rail from evaporating and keeps external dust from entering the rail, thereby avoiding jamming.
Exhaust treatment: In applications with extremely stringent cleanliness requirements (such as semiconductor wafer handling), it is recommended to equip with…Exhaust purifier, to prevent the compressed air discharged from the cylinder from stirring up dust on the ground.
Has this answer resolved your issue?
Total 50 People find this answer valuable.